Thermal Analysis --> Seebeck Coefficient / Electric Resistance


Seebeck - LSR - Seebeck Coefficient / Electric Resistance



The Thermal power, thermoelectric power, or Seebeck coefficient of a material measures the magnitude of an induced thermoelectric voltage in response to a temperature difference across that material. The thermal power has units of (V/K).
In recent years much interest has been shown in various methods of direct conversion of heat into electricity. Waste heat from hot engines and combustion systems could save billions of dollars if it could be captured and converted into electricity via thermoelectric devices
For this challenging application Linseis has developed a characteristic evaluating instrument for these materials and devices; the LSR-3 “Linseis - Seebeck & Electric Resistivity Unit”.


Features


The LSR - 3 can simultaneous measure both Seebeck coefficient and electric resistance (Resistivity).
 

  • Prism and cylindrical samples with a length between 6 to 22mm can be analyzed
  • Wires and Foils can be analyzed with a unique measurement adapter
  • Three different exchangeable furnaces cover the temperature range from -100 up to 1100°C
  • The design of the sample holder guarantees highest measurement reproducibility
  • State of the art 32-Bit software enables automatic measurement procedures
  • Measurement Data can be easily exported

 

Principles of Measurement

A sample of cylindrical or prism shape is vertically positioned between two electrodes. The lower electrode block contains a heater, whilst the entire measuring arrangement is located in a furnace.
The furnace surrounding the measuring arrangement heats the sample to a specified temperature. At this temperature the secondary heater in the lower electrode block creates a set temperature gradient. Two contacting thermocouples then measure the temperature gradient T1 and T2. A unique thermocouple contact mechanism permits highest accuracy measurements of the electromotive force dE at one wire of each of the two thermocouples.
The dc four-terminal method is used to measure the Electric Resistance. By applying a constant current (I) at both ends of the sample and measuring the change in voltage dV between one wires at each of the two thermocouple pares.

 

Other types:

TFA-Thin Film Analyzer

LZT-Meter (combined LSR/LFA)

 

 

Specifications

Temperature range*

- 100 to 500°C, RT up to 800°C, RT up to 1100°C

Specimen holder

Sandwiched between two electrodes

Measurement method

Seebeck coefficient: Static dc method 
Electric resistance: Four-terminal method

Atmosphere

inert, oxid., red., vac.

Sample size

2 to 4 mm square or diameter x 6 to 23 mm long (maximum)

Lead interval

4,6,8 mm

Cooling water requirements

required


* different furnaces available

Brochure for more information

share this page on your:

Facebook Twitter Google+ Linkedin


         

              

Compositional analysis of Lipids 20-21 June 2013

Anaspec Solutions and Oxford Instruments have introduced at this event the new Pulsar NMR, the benchtop NMR for SFC analysis. The location was in Het Pand in Ghent, Belgium. This event was organised bij SCI’s Lipids Group in Collaboration with Ghent University and EFL Physical Properties Division.

Read More

First meeting of the Benelux Lipid Network

Finally the first meeting of this new organization which took place at the premises of the campus in Ghent.

The meeting is the ideal platform for discussion and information exchange for scientists and technologists in Benelux in the business of edible oils & fats.

 

Read More

Brookhaven launched their new NanoBrook particle instrument.

Nanobrook

Brookhaven launched their new NanoBrook particle instrument with three angles. Knowing 15, 90 and 173°. So also backscattering is now available besides the others as well as in combination with zetapotential.

Read More